PROSOFT PTQ-PDPS 屏蔽連接器

如果狀態(tài)數(shù)據(jù)傳輸失敗,它將被記錄到事件日志中· “reading cmpVal 1(TagPath),trig TrigName”TagPath=標(biāo)記的完整路徑(例如EnetBridge\PLC5\N7:1)。TrigName=已配置的觸發(fā)器名稱?!?“reading cmpVal 2(TagPath),trig TrigName”TagPath=標(biāo)記的完整路徑(例如EnetBridge\PLC5\N7:1)。TrigName=已配置的觸發(fā)器名稱。PTQ-PDPS· “正在評(píng)估比較值,trigger TrigName”TrigName=已配置的觸發(fā)器名稱。注:這通常與數(shù)據(jù)比較錯(cuò)誤(850小時(shí)或851小時(shí))有關(guān)?!?“xferlist TransferListName,seq SequenceNumber”TransferListName=已配置的傳輸列表名稱。SequenceNumber=配置的傳輸列表序列號(hào)。注:這通常與數(shù)據(jù)轉(zhuǎn)換錯(cuò)誤(852h或853h)有關(guān)?!?“reading TagPath,xferList TransferListName,seq SequenceNumber”TagPath=標(biāo)記的完整路徑(例如EnetBridge\PLC5\N7:1)。TransferListName=已配置的傳輸列表名稱。SequenceNumber=配置的傳輸列表序列號(hào)。注意:這是由于傳輸源讀取錯(cuò)誤而發(fā)布的?!?“writing TagPath,xferList TransferListName,seq SequenceNumber”TagPath=標(biāo)記的完整路徑(例如EnetBridge\PLC5\N7:1)。PTQ-PDPS=已配置的傳輸列表名稱。SequenceNumber=配置的傳輸列表序列號(hào)。注意:這是由于傳輸目的地寫入錯(cuò)誤而導(dǎo)致的。6.4.8清除錯(cuò)誤計(jì)數(shù)傳輸狀態(tài)錯(cuò)誤計(jì)數(shù)可通過兩種方式共同清除:1機(jī)組重新啟動(dòng)。2“狀態(tài)運(yùn)行時(shí)傳輸列表”頁面上將提供一個(gè)清除傳輸狀態(tài)數(shù)據(jù)按鈕,如下所示。“writing TagPath,xferList TransferListName,seq SequenceNumber”TagPath=標(biāo)記的完整路徑(例如EnetBridge\PLC5\N7:1)。PTQ-PDPS=已配置的傳輸列表名稱。SequenceNumber=配置的傳輸列表序列號(hào)。




如果選擇了“繼續(xù)”技術(shù),則將嘗試傳輸列表中的每次傳輸,并通知任何錯(cuò)誤。o如果選擇了“中止”技術(shù),則會(huì)通知產(chǎn)生錯(cuò)誤的傳輸,但不會(huì)執(zhí)行傳輸列表的其余部分。錯(cuò)誤消息具有以下通用格式:ErrorCodeString ContextString其中:· ErrorCodeString=直接從錯(cuò)誤代碼派生的文本字符串。例如,掃描儀錯(cuò)誤代碼804h=“超時(shí)”。PTQ-PDPS· ContextString=上下文描述。例如,如果在讀取觸發(fā)器比較標(biāo)簽#1時(shí)發(fā)生錯(cuò)誤:· ContextString=“正在讀取cmpVal 1(TagPath),trig TrigName”,其中:· TagPath=配置定義的設(shè)備路徑和標(biāo)簽名稱,例如EnetBridge\PLC5\N7:1?!?TriggerName=配置定義的觸發(fā)器名稱。1h-1FFh范圍內(nèi)的錯(cuò)誤代碼屬于一般驅(qū)動(dòng)程序錯(cuò)誤。201h-7FFh中的代碼是驅(qū)動(dòng)程序特定的錯(cuò)誤(多于一個(gè)的驅(qū)動(dòng)程序可能具有錯(cuò)誤201h)。801h1FFFh中的代碼是掃描儀錯(cuò)誤。本文件中未具體列出的錯(cuò)誤可能需要工程干預(yù)來確定原因(內(nèi)部錯(cuò)誤、程序錯(cuò)誤或意外/罕見的通信錯(cuò)誤)。PTQ-PDPS正如您所看到的,ILX56-MM中的實(shí)際傳輸機(jī)制與消息傳遞層相距甚遠(yuǎn)。因此,許多錯(cuò)誤與掃描儀、驅(qū)動(dòng)程序和應(yīng)用程序編程接口(API)有關(guān)。如果未清除錯(cuò)誤計(jì)數(shù)值,則當(dāng)計(jì)數(shù)達(dá)到十進(jìn)制值65535時(shí),計(jì)數(shù)將翻轉(zhuǎn)為零,并且必須再次遞增?!皞鬏斿e(cuò)誤計(jì)數(shù)”不一定與“狀態(tài)運(yùn)行時(shí)傳輸列表”頁面上顯示的錯(cuò)誤計(jì)數(shù)相關(guān)。




Supported systems include: PTQ-PDPS Rockwell Automation (RA) ControlLogix (CLX) Programmable Automation Controller (PAC) systems ? RA CompactLogix? (CPLX) PAC systems ? Allen-Bradley? (A-B) PLC5? systems ? A-B SLC? systems ? A-B MicroLogix? systems ? Siemens S7? systems with Industrial Ethernet communications ? Schneider Electric? Quantum? PLC systems with Modbus TCP/IP communications ? Any devices that support Modbus TCP/IP ProtocolLearning Objectives When you have completed all the steps in this Setup Guide, you will have learned how to ? Understand how the sample application works PTQ-PDPS Install and Configure the ILX56-MM module ? Import the Add-On Instructions to the ControlLogix and CompactLogix processors (page 24) PTQ-PDPS Verify the ILX56-MM module communication status

 



if any 2 Module operation and any unusual behavior 3 Configuration/Debug status information 4 LED patterns 5 Details about the serial, Ethernet or Fieldbus devices interfaced to the module, if any. Note: For technical support calls within the United States,PTQ-PDPS ProSoft’s 24/7 after-hours phone support is available for urgent plant-down issues. Detailed contact information for all our worldwide locations is available on the following page.For complete details regarding ProSoft Technology’s TERMS & CONDITIONS OF SALE, WARRANTY, SUPPORT, SERVICE AND RETURN MATERIAL AUTHORIZATION INSTRUCTIONS, please see the documents at:gy PTQ-PDPS/legal Documentation is subject to change without notice.The ILX56-Message Manager is a communications interface that can be installed in a Rockwell Automation? ControlLogix?1756 chassis to provide data transfer functionality between automation systems based on a diverse range of controllers and processors.

NeoImage_副本.jpg


 “writing TagPath, xferList TransferListName, seq SequenceNumber” TagPath = Full path to tag (EnetBridge\PLC5\N7:1 for example). TransferListName = Configured transfer list name. SequenceNumber = Configured transfer list sequence number. Note: This is posted as a result of a transfer destination write error. 6.4.8 Clearing the Error Counts The transfer status error counts may be cleared collectively in two ways: 1 The unit is rebooted. 2 A Clear TRANSFER STATUS DATA button will be provided on the "Status-Runtime-Transfer Lists" page as shown below.PTQ-PDPS

ProSoft Technology, Inc. is committed to providing the most efficient and effective support possible. Before calling, please gather the following information to assist in expediting this process: 1 Product Version Number 2 System architecture 3 Network details If the issue is hardware related, we will also need information regarding: 1 Module configuration and associated ladder files, PTQ-PDPS