PROSOFT MVI56-LTQ 控制系統(tǒng)
MVI94-GSC-E MVI94-GSC-E MVI94-GSC-E可以通過(guò)設(shè)置“級(jí)別”來(lái)篩選顯示的事件。設(shè)置“級(jí)別將顯示指定級(jí)別或更低級(jí)別的事件。Level永遠(yuǎn)不能設(shè)置為大于掃描儀記錄事件的日志級(jí)別。可以通過(guò)按export XML按鈕將事件的有序列表導(dǎo)出到XML文件。在檢查事件日志時(shí),如果切換到其他頁(yè)面,然后切換回事件日志,事件日志將繼續(xù)顯示首次打開(kāi)事件日志時(shí)加載的事件。這將允許您在頁(yè)面之間來(lái)回切換時(shí)檢查事件日志,而無(wú)需重新加載日志。RESOURCE STATUS頁(yè)面顯示模塊上的當(dāng)前資源使用情況。要打開(kāi)“資源狀態(tài)”頁(yè)面,請(qǐng)單擊“狀態(tài)”選項(xiàng)卡,然后單擊“資源”選項(xiàng)卡。資源狀態(tài)使用情況包括平均CPU負(fù)載、已用內(nèi)存和已用閃存。UPDATE RATE指定資源狀態(tài)更新的時(shí)間(以秒為單位)。MVI94-GSC-E您可以選擇5、10、15或20秒的更新速率。產(chǎn)品規(guī)格ILX56-MM(“工業(yè)通信消息管理器”)允許羅克韋爾自動(dòng)化ControlLogix I/O兼容處理器與其他MM協(xié)議兼容設(shè)備輕松對(duì)接。6.1.1功能概述不同系統(tǒng)之間傳輸數(shù)據(jù)傳輸消息的主要方式是通過(guò)模塊上的兩個(gè)以太網(wǎng)端口。MVI94-GSC-E所有與西門子或施耐德電氣系統(tǒng)之間傳輸?shù)臄?shù)據(jù)都必須通過(guò)其中一個(gè)以太網(wǎng)端口完成。還可以使用RA處理器之間通用的EtherNet/IP協(xié)議在不同的RA系統(tǒng)之間傳輸數(shù)據(jù)。
MVI94-GSC-E以使用“內(nèi)部標(biāo)記”、ControlLogix、CompactLogix和FlexLogix的“新建標(biāo)記”對(duì)話框?qū)?biāo)記的參照添加到模塊的配置中?!づc指定篩選器匹配的標(biāo)簽將加載到標(biāo)簽樹(shù)中?;蛘?,要獲取所有標(biāo)簽,請(qǐng)將“標(biāo)簽過(guò)濾器”留空,然后按“獲取標(biāo)簽”按鈕。MVI94-GSC-E將與過(guò)濾器匹配的標(biāo)記加載到標(biāo)記樹(shù)中后,選擇一個(gè)標(biāo)記。與標(biāo)記關(guān)聯(lián)的圖元的名稱、數(shù)據(jù)類型和數(shù)量顯示在“新建標(biāo)記”對(duì)話框的右側(cè)。您不能修改任何標(biāo)記值。事件日志頁(yè)面顯示掃描儀最近記錄的事件。要打開(kāi)事件日志頁(yè)面,請(qǐng)單擊狀態(tài)選項(xiàng)卡,然后單擊事件日志選項(xiàng)卡。事件日志將顯示從最近的事件開(kāi)始記錄的事件。每個(gè)事件都有與其關(guān)聯(lián)的級(jí)別。級(jí)別為“1”表示該事件是一個(gè)錯(cuò)誤,而級(jí)別2“到”4“是重要性降低的信息事件。掃描儀將根據(jù)“管理/系統(tǒng)”頁(yè)上設(shè)置的“日志級(jí)別”來(lái)記錄事件。級(jí)別0是為內(nèi)部系統(tǒng)錯(cuò)誤保留的。模塊不會(huì)在發(fā)布了級(jí)別0錯(cuò)誤的情況下運(yùn)行。事件日志將顯示這些事件中最近的100個(gè)。若要顯示接下來(lái)的100個(gè)事件,請(qǐng)單擊“下一個(gè)100”按鈕。您可以繼續(xù)按“下一步100”按鈕,MVI94-GSC-E直到到達(dá)最后一組事件為止。MVI94-GSC-E按完“下一次100”按鈕后,您可以按“上一次100個(gè)”按鈕來(lái)查看上一組100個(gè)事件。若要檢索最新的事件日志,請(qǐng)單擊《重新加載》按鈕。
You may select an update rate of 5, 10, 15 or 20 seconds.Product Specifications The ILX56-MM ("Message Manager for Industrial Communication") allows Rockwell Automation ControlLogix I/O compatible processors to interface easily with other MM protocol compatible devices. 6.1.1 Functional Overview The primary means of transmitting data transfer messages between diverse systems is through the two Ethernet ports on the module. All data transferred to and from Siemens or Schneider Electric systems must be done via one of these Ethernet ports. Data may also be transferred between different RA systems using the EtherNet/IP protocol common among RA processors. The ILX56-MM can transfer data directly across the backplane to and from a ControlLogix PAC installed in the same chassis. This ability to communicate across the ControlLogix backplane means that the ILX56-MM can also take advantage of the "bridging" capability of certain RA communications modules and protocols.MVI94-GSC-E
When the Level is set, only events of the specified level or lower are displayed. The LEVEL can never be set greater than the Log Level at which the scanner is recording events. You can export the ordered list of events to an XML file by pressing the EXPORT XML button MVI94-GSC-E. When examining the Event Log, if you switch to another page and then switch back to the Event Log, the Event Log will continue to display the events that were loaded when the Event Log was first opened. This will allow you to examine the Event Log while switching back and forth between pages without having the log reloaded.The RESOURCE STATUS page shows you the current resource usage on the module. To open the Resource Status page, click the STATUS tab, then click the RESOURCE tab. The Resource Status usage includes the Average (Avg) CPU Load, the Memory Used, and the Compact Flash Storage Used. The UPDATE RATE specifies the time in seconds at which the Resource Status is updated.
The Event Logs page shows you recent events that have been logged by the scanner. To open the Event Logs page, click the STATUS tab, then click the EVENT LOGS tab.MVI94-GSC-E The Event Log will display events that have been logged starting with the most recent event. Each event has level associated with it. A level of "1" means the event is an error, while levels 2" through "4" are information events of decreasing importance. The scanner will log events based on the Log Level set on the Administration/System page. A level of 0 is reserved for internal system errors. The module will not run with a level 0 error posted. The Event Log will display the most recent 100 of these events. To display the next 100 events, click the NEXT 100 button. You can continue pressing the NEXT 100 button until you have reached the last set of events.MVI94-GSC-E After pressing the Next 100 button, you can view the previous set of 100 events by pressing the PREVIOUS 100 button. To retrieve the latest event logs, click the Reload button. You can filter which events are displayed by setting the LEVEL.