PROSOFT MVI69-PDPS 通訊卡
·Exe最小傳輸列表執(zhí)行時(shí)間(以毫秒為單位)。Exe最大傳輸列表執(zhí)行時(shí)間(以毫秒為單位)。大小傳輸?shù)拇笮。ㄒ宰止?jié)為單位)。錯(cuò)誤狀態(tài)標(biāo)志這是在第一次遇到錯(cuò)誤時(shí)設(shè)置的,并在下一次成功完成傳輸列表時(shí)清除。源狀態(tài)提供詳細(xì)的狀態(tài)信息,如“當(dāng)前錯(cuò)誤”、“最近的錯(cuò)誤”和“錯(cuò)誤歷史記錄”。目標(biāo)服務(wù)器提供詳細(xì)的狀態(tài)信息,如“當(dāng)前錯(cuò)誤”、“最近的錯(cuò)誤”和“錯(cuò)誤歷史記錄”。要在查看“運(yùn)行時(shí)傳輸列表狀態(tài)”頁面時(shí)更新狀態(tài),請(qǐng)單擊REFRESH按鈕。要在查看運(yùn)行時(shí)傳輸列表狀態(tài)頁面時(shí)重置所有運(yùn)行時(shí)統(tǒng)計(jì)信息,請(qǐng)單擊reset statistics按鈕。將診斷信息從MM傳輸?shù)骄W(wǎng)絡(luò)接口設(shè)備內(nèi)部標(biāo)簽(#I)提供運(yùn)行時(shí)狀態(tài)數(shù)據(jù)。每個(gè)用戶定義的觸發(fā)器、傳輸列表、接口和設(shè)備都將具有預(yù)定義的內(nèi)部接口狀態(tài)標(biāo)記。統(tǒng)計(jì)數(shù)據(jù)將以數(shù)據(jù)結(jié)構(gòu)的形式提供,這些數(shù)據(jù)結(jié)構(gòu)可以在一次傳輸中傳輸?shù)胶线m的UDT。統(tǒng)計(jì)數(shù)據(jù)也將作為單獨(dú)的值提供給不支持UDT的控制器???/span>
參數(shù)描述計(jì)數(shù)表示傳輸列表已完成的次數(shù)。Error表示傳輸列表I/O錯(cuò)誤的數(shù)量。Exe最近16次傳輸列表執(zhí)行時(shí)間的平均值(以毫秒為單位)。Exe最小傳輸列表執(zhí)行時(shí)間(以毫秒為單位)。Exe最大傳輸列表執(zhí)行時(shí)間(以毫秒為單位)。大小傳輸?shù)拇笮。ㄒ宰止?jié)為單位)。錯(cuò)誤狀態(tài)標(biāo)志這是在第一次遇到錯(cuò)誤時(shí)設(shè)置的,并在下一次成功完成傳輸列表時(shí)清除。源狀態(tài)提供詳細(xì)的狀態(tài)信息,如“當(dāng)前錯(cuò)誤”、“最近的錯(cuò)誤”和“錯(cuò)誤歷史記錄”。目標(biāo)服務(wù)器提供詳細(xì)的狀態(tài)信息,如“當(dāng)前錯(cuò)誤”、“最近的錯(cuò)誤”和“錯(cuò)誤歷史記錄”。要在查看“運(yùn)行時(shí)傳輸列表狀態(tài)”頁面時(shí)更新狀態(tài),請(qǐng)單擊REFRESH按鈕。要在查看運(yùn)行時(shí)傳輸列表狀態(tài)頁面時(shí)重置所有運(yùn)行時(shí)統(tǒng)計(jì)信息,請(qǐng)單擊reset statistics按鈕。運(yùn)行時(shí)傳輸列表狀態(tài)要打開“運(yùn)行時(shí)傳輸名單狀態(tài)”頁面,請(qǐng)單擊“狀態(tài)”選項(xiàng)卡,然后單擊“運(yùn)行時(shí)間”選項(xiàng)卡,再單擊“傳輸列表”選項(xiàng)卡。運(yùn)行時(shí)傳輸清單狀態(tài)頁面包含一個(gè)表,顯示掃描程序中定義的所有傳輸清單以及每個(gè)傳輸清單的信息。有關(guān)每個(gè)轉(zhuǎn)移列表的信息包括以下內(nèi)容。參數(shù)描述計(jì)數(shù)表示傳輸列表已完成的次數(shù)。Error表示傳輸列表I/O錯(cuò)誤的數(shù)量。Exe最近16次傳輸列表執(zhí)行時(shí)間的平均值(以毫秒為單位)。
ControlLogix, CompactLogix and FlexLogix to add references of tags to the module's configuration. ·ags that match the specified filter will be loaded into the tag tree. Or, to get all Tags, leave the Tag Filter empty and press the GET TAGS button. After the Tags which match the filter are loaded into the Tag tree, select a Tag. The Name, Data Type, and Number of Elements associated with the Tag are displayed on the right hand side of the New Tag dialog box. You cannot modify any of the Tag values.
MVI56-LTQ Restore Click the BROWSE button to select a previously saved configuration file from your computer. Click the RESTORE button to restore the module to the state saved in the configuration file. The module is rebooted after the configuration is restored. You will be prompted to confirm the configuration restore and reboot. Set Log Level Set the log level at which the scanner module will record events. § Level 1 logs errors only. This is the recommended setting for most applications. § Levels 2 through 4 log informational events in increasing detail. Use these levels for troubleshooting and support. § Level 0 logs only internal system errors. The scanner must be restarted before the new log level will take effect.MVI56-LTQ Click the REINITIALIZE button to restart the scanner. You will be prompted to confirm the reinitialize. Clear Event Logs Clears the entire Event Log from the module. This cannot be undone.
Recent Error, Error History. Destination Server Provides detailed status information such as Current Error, Recent Error, Error History. To update the status while viewing the Runtime Transfer Lists Status page, click the REFRESH button. To reset all of the runtime statistics while viewing the Runtime Transfer Lists Status page, click the RESET STATISTICS button.Tranferring Diagnostic Information from MM to Network Interface Devices Internal Tags (#I) provide runtime status data. Every user defined Trigger, Transfer List, Interface, and Device will have predefined internal Interface status tags. The statistics will be available in data structures which may be transferred to a suitable UDT in a single transfer. The statistics will also be available as individual values for transfer to controllers that do not support UDTs. You can use the New Tag dialog box for Internal Tags,