PROSOFT MVI69-MNET 多客戶端網(wǎng)絡(luò)接口模塊

 PROSOFT | 2024-01-18 09:45:16| 小編  提示:點(diǎn)擊圖片可以放大

PROSOFT MVI69-MNET 多客戶端網(wǎng)絡(luò)接口模塊

運(yùn)行時(shí)常規(guī)狀態(tài)要打開(kāi)“運(yùn)行時(shí)常規(guī)狀況”頁(yè)面,請(qǐng)單擊“狀態(tài)”選項(xiàng)卡,然后單擊“Runtime”選項(xiàng)卡,再單擊“Status”選項(xiàng)卡?!斑\(yùn)行時(shí)通用狀態(tài)”頁(yè)面將顯示當(dāng)前掃描儀模式、掃描儀處于當(dāng)前模式的時(shí)間、掃描儀中活動(dòng)的錯(cuò)誤數(shù)以及掃描儀記錄的錯(cuò)誤數(shù)。要在查看“運(yùn)行時(shí)常規(guī)狀態(tài)”頁(yè)面時(shí)更新?tīng)顟B(tài),請(qǐng)單擊REFRESH按鈕。另請(qǐng)參閱狀態(tài)(MVI69-MNET)和運(yùn)行時(shí)狀態(tài)(MVI69-MNET)。Runtime Interface Status要打開(kāi)Runtime Interface Status頁(yè)面,請(qǐng)單擊Status選項(xiàng)卡,然后單擊Runtime選項(xiàng)卡,MVI69-MNET再單擊Interface選項(xiàng)卡。Runtime Interface Status頁(yè)包含一個(gè)表,顯示掃描儀中定義的所有接口以及每個(gè)接口的信息。關(guān)于每個(gè)接口的信息包括以下內(nèi)容。參數(shù)描述計(jì)數(shù)指示接口已啟動(dòng)的次數(shù)。數(shù)據(jù)包重試計(jì)數(shù)指示數(shù)據(jù)包發(fā)送被重新發(fā)送到控制器的次數(shù)MVI69-MNET。數(shù)據(jù)包錯(cuò)誤計(jì)數(shù)指示向控制器發(fā)送數(shù)據(jù)包時(shí)發(fā)生錯(cuò)誤的次數(shù)。標(biāo)記訪問(wèn)計(jì)數(shù)控制器中的標(biāo)記被訪問(wèn)(讀取或?qū)懭耄┑目偞螖?shù)。MVI69-MNET 標(biāo)記訪問(wèn)錯(cuò)誤計(jì)數(shù)在控制器中讀取或?qū)懭霕?biāo)記時(shí)發(fā)生的錯(cuò)誤總數(shù)。錯(cuò)誤狀態(tài)標(biāo)志驅(qū)動(dòng)程序或設(shè)備中出現(xiàn)的當(dāng)前錯(cuò)誤編號(hào)。當(dāng)它們沒(méi)有錯(cuò)誤時(shí),這將被清除。




要重置網(wǎng)絡(luò)端口設(shè)置,請(qǐng)轉(zhuǎn)至網(wǎng)絡(luò)設(shè)置(第19頁(yè))。重置完網(wǎng)絡(luò)端口設(shè)置和/或默認(rèn)管理員密碼后,1關(guān)閉web瀏覽器。2從ControlLogix機(jī)架上卸下模塊。3拆下設(shè)置模式跳線。4將模塊重新安裝到ControlLogix機(jī)架中。5.3狀態(tài)要查看模塊的狀態(tài)信息,請(qǐng)單擊狀態(tài)選項(xiàng)卡。無(wú)需登錄模塊即可查看狀態(tài)信息。另請(qǐng)參閱設(shè)備狀態(tài)(第55頁(yè))、運(yùn)行時(shí)狀態(tài)(第56頁(yè))、事件日志(第64頁(yè))、機(jī)箱狀態(tài)(第65頁(yè))和資源狀態(tài)(第66頁(yè))。要打開(kāi)設(shè)備狀態(tài)頁(yè)面,請(qǐng)單擊狀態(tài)選項(xiàng)卡,然后單擊設(shè)備選項(xiàng)卡。設(shè)備狀態(tài)頁(yè)面允許您查看當(dāng)前設(shè)備信息。設(shè)備信息包括以下內(nèi)容。參數(shù)描述名稱模塊的名稱。說(shuō)明模塊的說(shuō)明。位置模塊的位置。聯(lián)系模塊負(fù)責(zé)人。序列號(hào)模塊的序列號(hào)。MAC ID模塊的MAC ID。發(fā)布級(jí)別模塊的發(fā)布級(jí)別??梢栽凇肮芾?設(shè)備”頁(yè)面上修改設(shè)備信息。要查看模塊的運(yùn)行時(shí)狀態(tài)信息,請(qǐng)單擊Status選項(xiàng)卡,然后單擊Runtime選項(xiàng)卡。DOWNLOAD CROSS REFERENCE按鈕將生成配置中使用的所有活動(dòng)標(biāo)記、觸發(fā)器和傳輸列表的Excel交叉引用報(bào)告。生成的文件將是XLS文件(Excel 2000-2003)。如果您試圖用Excel 2007打開(kāi)此文件,您將收到一條警告,告訴您該文件的格式不同。如果出現(xiàn)這種情況,請(qǐng)單擊“是”以打開(kāi)此文件嗎?“運(yùn)行時(shí)接口狀態(tài)”頁(yè)面包含一個(gè)表,該表顯示掃描儀中定義的所有接口以及每個(gè)接口的信息。有關(guān)每個(gè)接口的信息包括在以下主題中。




The Runtime Triggers Status page contains a table that shows all of the Triggers that are defined in the scanner along with information about each Trigger. The information about each Trigger includes the following. Parameter Description Count Indicates the number of times the Trigger has fired. Error Indicates the number of Trigger evaluation I/O errors. Execution (Exe) Statistics are recorded only when the trigger fires. This is the time from Trigger Condition evaluation start to when the last triggered transfer list is complete. Parameter Description Exe Average Average in milliseconds of the last 16 Trigger execution times. Exe Min Minimum Trigger execution time in milliseconds. Exe Max Maximum Trigger execution time in milliseconds

 



Packet Retry Count Indicates the number of times a packet send was re-sent to the controller. Packet Error Count Indicates the number of times an error occurred sending a packet to the controller. Tag Access Count the total number of times that the tags in the controller have been accessed ( read or write). Tag Access Error Count The total number of errors that have occurred in while reading or writing tags in the controller. Error State Flag the current error number occurring in the driver or device. This gets cleared when their is no error. Details A string that describes the last error that occurred in the driver or device. This does NOT get cleared when the error goes away.Runtime Triggers Status To open the Runtime Triggers Status page, click the STATUS tab, then click the RUNTIME tab, then click the TRIGGERS tab. 

NeoImage_副本.jpg


 The information about each Interface is included the following topics. Runtime General Status To open the Runtime General Status page, click the STATUS tab, and then click the RUNTIME tab, then click the STATUS tab. The Runtime General Status page will show you the current scanner mode, the time that the scanner has been in the current mode, the number of errors active in the scanner, and the number of errors logged by the scanner. To update the status while viewing the Runtime General Status page, click the REFRESH button. See also Status (page 54), and Runtime Status (page 56). Runtime Interface Status To open the Runtime Interface Status page, click the STATUS tab, then click the RUNTIME tab, then click the INTERFACE tab. The Runtime Interface Status page contains a table that shows all of the Interfaces that are defined in the scanner along with information about each Interface. The information about each Interface includes the following. Parameter Description Count Indicates the number of times the Interface has fired.