有時(shí)您將無法登錄到模塊。當(dāng)另一個(gè)用戶登錄到模塊或您從另一個(gè)瀏覽器登錄到模塊時(shí),會(huì)發(fā)生這種情況。您必須等到其他用戶注銷后才能登錄到模塊。當(dāng)您關(guān)閉瀏覽器時(shí),配置工具會(huì)自動(dòng)將您注銷。但是,如果瀏覽器崩潰或鎖定,它將無法自動(dòng)將您注銷。在這種情況下,10分鐘的計(jì)時(shí)器會(huì)讓用戶保持登錄狀態(tài)。10分鐘后,用戶登錄將被釋放,您可以再次登錄。設(shè)置模式設(shè)置模式將模塊的網(wǎng)絡(luò)端口設(shè)置臨時(shí)設(shè)置為默認(rèn)值。設(shè)置模式還允許您重置默認(rèn)的ADMIN密碼。要進(jìn)入設(shè)置模式,必須從MVI69-MCM機(jī)架上卸下模塊。將設(shè)置模式跳線安裝在設(shè)置跳線的背面(第12頁)。然后將模塊插回MVI69-MCM機(jī)架。模塊現(xiàn)在處于設(shè)置模式,直到您卸下設(shè)置模式跳線。在設(shè)置模式下,模塊的網(wǎng)絡(luò)端口設(shè)置會(huì)臨時(shí)設(shè)置為默認(rèn)值。端口1設(shè)置為靜態(tài)IP地址192.168.1.254。端口2設(shè)置為從DHCP服務(wù)器獲取其IP。當(dāng)您在模塊處于設(shè)置模式時(shí)啟動(dòng)配置工具時(shí),頁面底部的狀態(tài)欄上會(huì)顯示一個(gè)紅色指示燈。在此模式下,用戶登錄被禁用,用戶可以使用所有管理員功能。要重置默認(rèn)的“admin”密碼,請單擊狀態(tài)欄上的reset admin password按鈕。此操作將恢復(fù)默認(rèn)的管理員用戶和密碼,并分配管理員權(quán)限。
關(guān)聯(lián)的觸發(fā)器將被禁用,直到掛起的傳輸列表開始并完成。如果在讀取觸發(fā)器比較值1或比較值2標(biāo)記時(shí)發(fā)生錯(cuò)誤,則該錯(cuò)誤將被置于活動(dòng)錯(cuò)誤列表中,記錄該錯(cuò)誤,并且觸發(fā)器將被禁用一段時(shí)間(通常為5秒,以防止錯(cuò)誤記錄過多)。如果或當(dāng)重試讀取失敗的比較值1/比較值2成功時(shí),活動(dòng)錯(cuò)誤將被清除,但日志條目將保留。有幾種方法可以驗(yàn)證ILX56-MM模塊是否與處理器和網(wǎng)絡(luò)通信:· 查看數(shù)據(jù)傳輸查看MVI69-MCM模塊中的數(shù)據(jù)傳輸統(tǒng)計(jì)信息(MVI69-MCM)· 查看觸發(fā)器查看ILX56-MM模塊中的觸發(fā)器統(tǒng)計(jì)信息(MVI69-MCM)· 查看查看控制器標(biāo)簽(第52頁MVI69-MCM)中的標(biāo)簽。查看控制器標(biāo)記如果ILX56-MM模塊在網(wǎng)絡(luò)上成功通信,您應(yīng)該能夠在每個(gè)處理器的編程軟件中看到標(biāo)記值的變化。如果數(shù)據(jù)傳輸正確進(jìn)行,您應(yīng)該能夠定位和監(jiān)視處理器中與您在ILX56-MM中配置的標(biāo)記相對應(yīng)的標(biāo)記、數(shù)據(jù)文件或內(nèi)存地址。有時(shí)您將無法登錄到模塊。當(dāng)另一個(gè)用戶登錄到模塊或您從另一個(gè)瀏覽器登錄到模塊時(shí),會(huì)發(fā)生這種情況。您必須等到其他用戶注銷后才能登錄到模塊。當(dāng)您關(guān)閉瀏覽器時(shí),配置工具會(huì)自動(dòng)將您注銷。但是,如果瀏覽器崩潰或鎖定,它將無法自動(dòng)將您注銷。在這種情況下,10分鐘的計(jì)時(shí)器會(huì)讓用戶保持登錄狀態(tài)。10分鐘后,用戶登錄將被釋放,您可以再次登錄。
MVI69-MCM he Device Status page allows you to view the current device information. The device information includes the following. Parameter Description Name Name of the module. Description Description of the module. Location Location of the module. Contact The person responsible for the module. Serial Number The serial number of the module. MAC ID The MAC ID of the module. Release Level The release level of the module. The device information can be modified on the Administration/Device page.To view Runtime Status information for the module, click the STATUS tab, then click the RUNTIME tab. The DOWNLOAD CROSS REFERENCE button will generate an Excel cross reference report of all of the active tags, triggers, and transfer lists being used in the configuration. The file generated will be an XLS file (Excel 2000-2003). If you attempt to open this file with Excel 2007 you will receive an alert telling you the file is of a different format. If this occurs, click YES to Do you want to open this file? The Runtime Interfaces Status page contains a table that shows all of the Interfaces that are defined in the scanner along with information about each Interface.MVI69-MCM
To reset the default "admin" password, click the RESET ADMIN PASSWORD button on the status bar. This action restores the default admin user and password,MVI69-MCM and assigns Administrator privilege. To reset the network port settings, go to the Network Settings (page 19). When you have finished resetting the network port settings and/or the default admin password, 1 Close your web browser.MVI69-MCM 2 Remove the module from the ControlLogix rack. 3 Remove the Setup Mode jumper. 4 Reinstall the module in the ControlLogix rack. 5.3 Status To view Status information for the module, click the STATUS tab. Status information can be viewed without logging in to the module. See also Device Status (page 55), Runtime Status (page 56), Event Logs (page 64), Chassis Status (page 65), and Resource Status (page 66).MVI69-MCM To open the DEVICE STATUS page, click the STATUS tab, and then click the DEVICE tab. T
Setup Mode Setup Mode temporarily sets the module's network port settings to their default values. Setup Mode also allows you to reset the default ADMIN password.MVI69-MCM To go into Setup Mode, you must remove the module from the ControlLogix rack. Install the Setup Mode jumper on the back of the Setup Jumper (page 12). Then plug the module back into the ControlLogix rack.MVI69-MCM The module is now in Setup Mode until you remove the Setup Mode jumper.MVI69-MCM When in Setup Mode, the module's network port settings are temporarily set to their default values. Port 1 is set to a static IP address of 192.168.1.254. Port 2 is set up to get its IP from a DHCP server. When you start the configuration tool while the module is in Setup Mode, a red indicator is displayed on the status bar at the bottom of the pageUser login is disabled in this mode and all Administrator functions are available to the user.