PROSOFT MVI56-MCMR 主/從網(wǎng)絡(luò)接口模塊

 PROSOFT | 2024-01-18 09:08:57| 小編  提示:點(diǎn)擊圖片可以放大

PROSOFT MVI56-LTQ 控制系統(tǒng) 

MVI56-MCMR單擊“刪除”按鈕以刪除選定的對(duì)象?;蛘?,選擇一個(gè)對(duì)象,然后按[DEL]鍵刪除(永久刪除)該對(duì)象。要使用配置編輯器,請(qǐng)展開(kāi)樹(shù)狀視圖(左窗格),然后選擇要編輯的對(duì)象?!?單擊工具欄上的“新建”按鈕,MVI56-MCMR在選定對(duì)象下創(chuàng)建一個(gè)新對(duì)象。· 單擊“編輯”按鈕以查看或修改選定的對(duì)象。或者,您可以雙擊樹(shù)狀圖中的選定對(duì)象?!?單擊“刪除”按鈕以刪除選定的對(duì)象?;蛘?,選擇一個(gè)對(duì)象,然后按[DEL]鍵刪除(永久刪除)該對(duì)象?!?Timeout指定與設(shè)備通信時(shí)使用的超時(shí)值(以毫秒為單位)。· 尋址信息包含對(duì)網(wǎng)絡(luò)上或設(shè)備所在機(jī)架中的設(shè)備進(jìn)行尋址的信息。根據(jù)接口類(lèi)型和設(shè)備類(lèi)型,也可以使用其他參數(shù)。下表介紹了每種接口/設(shè)備類(lèi)型的尋址參數(shù)。參數(shù)描述接口尋址被指定為插槽編號(hào)。MVI56-MCMR網(wǎng)橋?qū)ぶ繁恢付楣?jié)點(diǎn)號(hào)。DHRIO網(wǎng)橋?qū)ぶ繁恢付橥ǖ篮凸?jié)點(diǎn)號(hào)。MVI56-MCMR網(wǎng)橋?qū)ぶ分付橥ǖ篮凸?jié)點(diǎn)號(hào) · · · 單擊“編輯”按鈕以查看或修改選定的對(duì)象。或者,您可以雙擊樹(shù)狀圖中的選定對(duì)象?!?/span>




MVI56-MCMR右側(cè)窗格顯示您在樹(shù)狀圖中選擇的對(duì)象的屬性。下表介紹了可以配置的對(duì)象類(lèi)型。名稱(chēng)描述接口位于ControlLogix機(jī)架插槽中的物理對(duì)象,或連接到模塊端口的物理對(duì)象。設(shè)備將控制器鏈接到其中一個(gè)接口的物理對(duì)象(網(wǎng)橋)。MVI56-MCMR。標(biāo)記控制器中可以傳輸?shù)搅硪粋€(gè)控制器的單個(gè)數(shù)據(jù)對(duì)象。MVI56-MCMR。MVI56-MCMR觸發(fā)器定義何時(shí)將數(shù)據(jù)從一個(gè)接口(可編程控制器)傳輸?shù)搅硪粋€(gè)接口。請(qǐng)參閱觸發(fā)器(MVI56-MCMR)。傳輸列表定義要在設(shè)備之間傳輸?shù)臄?shù)據(jù)。MVI56-MCMR要使用配置編輯器,請(qǐng)展開(kāi)樹(shù)狀視圖(左窗格),然后選擇要編輯的對(duì)象?!?單擊工具欄上的“新建”按鈕,在選定對(duì)象下創(chuàng)建一個(gè)新對(duì)象?!?單擊“編輯”按鈕以查看或修改選定的對(duì)象?;蛘撸梢噪p擊樹(shù)狀圖中的選定對(duì)象。




A ControlNet bridge in a remote rack can be connected to a ControlLogix PLC in that rack or an EtherNet/IP bridge, ControlNet bridge, DHRIO bridge, MVI56-MCMR or DH485 bridge in that remote rack.DH485 Bridge A DH485 bridge in the local rack can be connected directly to an SLC, MicroLogix, or ControlLogix PAC, or, connected to another DH485 bridge in a remote ControlLogix rack. A DH485 bridge in a remote rack can be connected to a ControlLogix PAC in that rack or an EtherNet/IP bridge, ControlNet bridge, DHRIO bridge, or DH485 bridge in that remote rack.ControlLogix PLC A ControlLogix PAC in the local rack can be connected through a bridge module to a PLC 5, SLC, MicroLogix,MVI56-MCMR or ControlLogix PAC, or, connected to another ControlLogix PAC in a remote ControlLogix rack. A ControlLogix PAC in a remote rack can be connected to a ControlLogix PAC in that rack or an EtherNet/IP bridge, ControlNet bridge, DHRIO bridge, or DH485 bridge in that remote rack.An Interface defined as a Siemens S7 will contain a Tags node under it in the Configuration Editor tree. The Tags node contains all the Tags referenced for that controller.MVI56-MCMR

 



The ILX56-MM supports the following bridges: · EtherNet/IP Bridge (page 35) · DHRIO Bridge (page 35) · DH485 Bridge (page 37) ·MVI56-MCMR ControlNet Bridge (page 36)? EtherNet/IP Bridge A 1756 EtherNet/IP bridge in the local rack can be connected directly to a PLC 5, SLC, or MicroLogix. An EtherNet/IP bridge can also be connected to another EtherNet/IP bridge or CompactLogix PAC in a remote rack. An EtherNet/IP bridge in a remote rack can be connected to a ControlLogix PAC in that rack or an EtherNet/IP bridge, ControlNet bridge, DHRIO bridge, or DH485 bridge in that remote rack. An EtherNet/IP bridge rack can be connected to a CompactLogix PAC.DHRIO Bridge A DHRIO bridge in the local rack can be connected directly to a PLC 5 or SLC, or,MVI56-MCMR connected to another DHRIO bridge in a remote ControlLogix rack. A DHRIO bridge in a remote rack can be connected to a ControlLogix PAC in that rack or an EtherNet/IP bridge,MVI56-MCMR ControlNet bridge, DHRIO bridge, or DH485 bridge in that remote rack.ControlNet Bridge A ControlNet bridge in the local rack can be connected directly to a PLC 5 or, connected to another ControlNet bridge in a remote ControlLogix rack. 

NeoImage_副本.jpg


 Click the EDIT button to view or modify the selected object. Or, you can double-click the selected object in the tree view. · Click the DELETE button to delete the selected object. Or, select an object and then press the [DEL] key to Delete (permanently remove) the object.· The Timeout specifies the timeout value in milliseconds to be used in communicating with the device.MVI56-MCMR · The addressing information contains information to address the device on the network or in the rack where the device is located. Depending on the Interface Type and Device Type, other parameters may also be available. The following table describes the addressing parameters for each interface/device type. Parameter Description Interfaces Addressing is specified as a slot number.MVI56-MCMR ControlNet bridge Addressing is specified as a node number. DHRIO bridge Addressing is specified as a channel and node number. DH485 bridge Addressing is specified as a channel and node numberBridges (ControlLogix Backplane) Devices are configured under a bridge interface in the local rack. Select the DEVICES node in the Configuration Editor tree.MVI56-MCMR The content pane will display a table containing all of the Devices defined for that bridge.