PROSOFT MVI56-GEC 通用串行

 PROSOFT | 2024-01-18 08:48:02| 小編  提示:點(diǎn)擊圖片可以放大

PROSOFT MVI56-GEC 通用串行

維修工具軟件位于MVI56-GEC(個(gè)人電腦)上,并通過驅(qū)動(dòng)程序的9針維修端口與ProAct驅(qū)動(dòng)程序通信。各種用戶可使用以下模式:出廠校準(zhǔn)、測(cè)試、配置、用戶校準(zhǔn)、調(diào)整和監(jiān)控模式(見下圖的操作模式)。工廠校準(zhǔn)和測(cè)試模式是Woodward內(nèi)部獨(dú)有的選項(xiàng);客戶可以使用其他所有功能。維修工具模式受密碼保護(hù),以防止無(wú)意中更改程序。MVI56-GEC功能始終可用,不受密碼保護(hù)。為了安全起見,只有在機(jī)組關(guān)閉時(shí)才能進(jìn)入密碼保護(hù)模式。可以通過維修工具命令或打開低功率待機(jī)模式離散輸入來關(guān)閉機(jī)組。

 


連接到模塊的網(wǎng)頁(yè)如果您的網(wǎng)絡(luò)配置為使用MVI56-GEC范圍內(nèi)的IP地址,請(qǐng)打開MVI56-GEC(版本7或更高版本),然后連接到以下地址:MVI56-GEC如果您的網(wǎng)絡(luò)配置為使用不同的IP范圍,請(qǐng)執(zhí)行以下步驟:1斷開電腦與網(wǎng)絡(luò)的連接2連接電腦上的以太網(wǎng)端口和模塊上的端口1之間的以太網(wǎng)電纜3臨時(shí)更改電腦上的IP地址和子網(wǎng)掩碼以匹配模塊上的網(wǎng)絡(luò)配置:IP地址:MVI56-GEC子網(wǎng)掩碼:MVI56-GEC重要提示:記下您的IP地址設(shè)置。在重新連接到網(wǎng)絡(luò)之前,您需要恢復(fù)這些設(shè)置。



 Connect to the module's web page again at the module's new IP address. The following table describes the default Ethernet port configuration and login information. Factory Default settings Ethernet Ports: Port 1 Port 2 IP: 192.168.1.254. DHCP User Name: admin Password: admin Important: The User Name and Password are case-sensitive. 1.8 Logging In You can view the status and configuration of the MVI56-GEC without logging in. However, to modify the module's configuration, or to perform maintenance tasks, you must log in. The LOGIN and LOGOUT buttons are located in the status bar at the bottom of the module's web page. To Log In Click the LOGIN button on the status bar at the bottom of the page.The module has two RJ45 Ethernet ports, located at the bottom of the front panel on the module. 



Open Microsoft Internet Explorer (version 7, or higher) and connect to the following address:MVI56-GEC Click the LOGIN button at the bottom of the screen, and use the following username and password to login. Username: admin Password: admin 6 Click the MVI56-GECtab, and then the MVI56-GECtab. Configure the IP Address, Subnet Mask, and Default Gateway to work with your network. 7 Click the SAVE button to apply the updated settings 8 Change the IP Address and Subnet Mask settings on your PC back to their original values, and then reconnect your PC to the network.


NeoImage_副本.jpg


Connect to the Module's Web Page If your network is configured to use IP addresses in the rangeMVI56-GEC, open Microsoft Internet Explorer (version 7, or higher), and connect to the following address: MVI56-GECIf your network is configured to use a different IP range, follow these steps: 1 Disconnect your PC from the network 2 Connect the Ethernet cable between the Ethernet port on your PC and Port 1 on the module 3 Temporarily change the IP address and Subnet Mask on your PC to match the network configuration on the module: IP address: MVI56-GEC Subnet mask: MVI56-GEC Important: Make a note of your IP Address settings. You will need to restore these settings before you reconnect to the network.