LAM 810-800086-007 電源
810-800086-007最大占空比(%)默認(rèn)為90%(范圍10–90)PWM最大執(zhí)行器位置占空比設(shè)置,單位為百分比。該設(shè)置對(duì)應(yīng)于要求執(zhí)行機(jī)構(gòu)全開(kāi)(100%)的占空比(必須大于“PwmIn Min duty(%)”設(shè)置)。PwmIn頻率(Hz)dflt 1000 Hz(100–3000)標(biāo)稱PWM信號(hào)頻率(赫茲)。PwmIn Invert Input Signal dflt=false(false,true)Invert PWM Signal(反相PWM信號(hào))選項(xiàng)。此配置設(shè)置適用于810-800086-007輸出中沒(méi)有上拉的系統(tǒng)(有關(guān)詳細(xì)信息,810-800086-007)。此設(shè)置反轉(zhuǎn)PWM輸入值以讀取時(shí)間低的百分比,而不是時(shí)間高的百分比。調(diào)整用戶停止和動(dòng)力學(xué)簡(jiǎn)介維修工具的用戶校準(zhǔn)模式提供了設(shè)置最小和最大位置的功能,以匹配致動(dòng)器和閥門(mén)的索具。自動(dòng)和手動(dòng)程序都可用于執(zhí)行此設(shè)置。此校準(zhǔn)必須在裝置運(yùn)行之前完成。如果不執(zhí)行此程序,執(zhí)行機(jī)構(gòu)將默認(rèn)為(0到100)%的位置需求將對(duì)應(yīng)0到75度的旋轉(zhuǎn)。810-800086-007。一旦執(zhí)行了用戶校準(zhǔn),此程序?qū)⒒顒?dòng)的最小和最大位置存儲(chǔ)到非易失性存儲(chǔ)器中,在執(zhí)行新的校準(zhǔn)之前,該位置一直保留。此外,此模式可用于通過(guò)提供手動(dòng)沖程機(jī)構(gòu)來(lái)驗(yàn)證設(shè)置/校準(zhǔn)。810-800086-007
AnlgIn 200最小值(mA)dflt=20 mA(范圍0.0–200)810-800086-007模擬輸入最小需求值,單位為mA。此設(shè)置對(duì)應(yīng)于要求致動(dòng)器完全關(guān)閉(0%)的毫安信號(hào)(應(yīng)小于“AnlgIn 200Max Value(mA)”設(shè)置)。AnlgIn 200最大值(mA)dflt=180 mA(范圍0.0–200)模擬輸入最大需求值,單位為mA。此設(shè)置對(duì)應(yīng)于要求致動(dòng)器完全打開(kāi)(100%)的毫安信號(hào)(應(yīng)大于“AnlgIn 200Min Value(mA)”設(shè)置)。CAN數(shù)據(jù)速率默認(rèn)值=1(1,3)810-800086-007CAN數(shù)據(jù)速率設(shè)置,單位為kbps。選擇選項(xiàng):1=250、2=500、3=1000 kbps。CAN擴(kuò)展默認(rèn)值=1(0,1)CAN擴(kuò)展配置。這決定了CAN通信的消息。ProAct使用J1939 CAN,但此設(shè)置設(shè)置了要通過(guò)通信鏈路使用的實(shí)際參數(shù)組號(hào)(PGN)和可疑參數(shù)號(hào)(SPN)。選擇選項(xiàng):0=禁用Can通信,1=設(shè)置#1,2=設(shè)置#2等(如果配置了Can需求,則必須大于零)。810-800086-007最小占空比(%)默認(rèn)值=10%(范圍10–90)PWM最小執(zhí)行器位置占空比設(shè)置,單位為百分比。該設(shè)置對(duì)應(yīng)于要求致動(dòng)器完全關(guān)閉的占空比(0%)(必須小于“PwmIn Max duty(%)”設(shè)置)。
This configuration setting is available for systems that do not have a pull-up in their PWM output (refer to the hardware PWM section for details).810-800086-007 This setting inverts the PWM input values to read the percentage of the time low rather than the percentage of the time high. Adjusting User Stops and Dynamics Introduction The User Calibration mode of the Service Tool provides the capability to set the min and max position to match the rigging of the actuator and valve. Both automatic and manual procedures are available to perform this setup.810-800086-007 This calibration must be done prior to operation of the unit.810-800086-007 If this procedure is not done, the actuator will be defaulted such that (0 to 100) % position demand will correspond to 0–75 degrees rotation. Refer to Figure 9-4. Once the user calibration is performed, this procedure stores the active min and max positions into non-volatile memory where it is retained until a new calibration is performed. 810-800086-007In addition, this mode can be used to verify the setup/calibration by providing a manual stroking mechanism.
The ProAct uses J1939 CAN but this setting sets up the actual Parameter Group Numbers (PGNs) and Suspect Parameter Numbers (SPNs) to be used over the comm link.810-800086-007 Selection options: 0=Disable Can communications, 1=Set#1, 2=Set#2, etc.810-800086-007 (must be greater than zero if CAN demand is configured). PwmIn Min Duty (%) default = 10 % (range 10–90) PWM Minimum actuator position Duty Cycle setting in percent. This setting corresponds to the duty cycle that would demand the actuator to be fully closed (0 %) (must be less than the ’PwmIn Max Duty (%)’ setting). PwmIn Max Duty (%) default 90 % (range 10–90) PWM Maximum actuator position Duty Cycle setting in percent. This setting corresponds to the duty cycle that would demand the actuator to be fully open (100 %) (must be greater than the ‘PwmIn Min Duty (%)’ setting).810-800086-007 PwmIn Frequency (Hz) dflt 1000 Hz (100–3000) Nominal PWM signal frequency in hertz. PwmIn Invert Input Signal dflt =false (false, true) Invert PWM Signal option.
AnlgIn 200 Min Value (mA) dflt= 20 mA(range 0.0–200) Analog Input Minimum Demand Value in mA. This setting corresponds to the milliamp signal that would demand the actuator to be fully closed (0 %) (should be less than the ’AnlgIn 200 Max Value (mA)’ setting)810-800086-007 AnlgIn 200 Max Value (mA) dflt=180 mA (range 0.0–200) Analog Input Maximum Demand Value in mA. This setting corresponds to the milliamp signal that would demand the actuator to be fully opened (100 %) (should be greater than the ’AnlgIn 200 Min Value (mA)’ setting).810-800086-007 CAN DataRate default = 1(1, 3) CAN data rate setting in kbps. Selection options: 1=250, 2=500, 3=1000 kbps. CAN Extensions default = 1 (0, 1) CAN Extension Configuration.810-800086-007 This determines the messages of the CAN communications.