LAM 810-800031-400 PCB板
產(chǎn)品概述:
810-800031-400此命令可以在true和false之間切換。當(dāng)切換到true時(shí),機(jī)組將保持關(guān)閉狀態(tài),直到該參數(shù)設(shè)置回false或ProAct上的電源循環(huán)。狀態(tài)-報(bào)警-報(bào)警條件存在的一般指示,具體報(bào)警條件請(qǐng)參閱狀態(tài)錯(cuò)誤-報(bào)警選項(xiàng)卡頁(yè)。Status–Shutdown–存在Shutdown條件的一般指示,有關(guān)特定條件,請(qǐng)參閱Status Error–Shutdowns選項(xiàng)卡頁(yè)。狀態(tài)-低功率標(biāo)準(zhǔn)差-機(jī)組處于低功率待機(jī)模式的一般指示,810-800031-400有關(guān)具體情況,請(qǐng)參閱狀態(tài)錯(cuò)誤-停機(jī)選項(xiàng)卡頁(yè)。服務(wù):位置控制位置控制選項(xiàng)卡工作表包含位置控制信息。位置需求(%)——基于裝置配置的實(shí)際位置需求信號(hào)的指示,單位為用戶校準(zhǔn)范圍的百分比。實(shí)際位置(%)——實(shí)際傳動(dòng)軸輸出位置的指示,單位為用戶校準(zhǔn)范圍的百分比。810-800031-400實(shí)際位置(度)——相對(duì)于絕對(duì)軸位置的實(shí)際驅(qū)動(dòng)軸輸出位置的指示,單位為旋轉(zhuǎn)度。對(duì)于型號(hào)I至IV,完全逆時(shí)針方向?yàn)?度,完全順時(shí)針方向?yàn)?5度。
Mode Int——模式字符串的整數(shù)指示(見上文)810-800031-400。ProAct軟件版本--顯示已安裝軟件的版本號(hào)。Config ID--顯示可配置軟件系統(tǒng)的標(biāo)識(shí)。此參數(shù)的默認(rèn)值為ProAct Digital Plus Configuration,但此字符串可以在CFG文件中編輯為相對(duì)于特定應(yīng)用程序設(shè)置更有意義的名稱,然后下載回ProAct控件。CAN ProAct Number(CAN ProAct編號(hào))—表示CAN通信中使用的識(shí)別號(hào)。基于上電時(shí)CAN ID Hi和Lo離散輸入的狀態(tài)。電子溫度(°C)——檢測(cè)到的電子設(shè)備溫度的指示,單位為攝氏度。RunTime–810-800031-400清除命令—清除累積運(yùn)行時(shí)間的命令。RunTime–Hours--自上次發(fā)出Run Time Clear命令以來(lái)的累計(jì)運(yùn)行時(shí)數(shù)。每當(dāng)裝置通電并按小時(shí)存儲(chǔ)時(shí),或啟用低功率待機(jī)模式離散輸入時(shí),時(shí)間就會(huì)累積。RunTime–100mSec——累計(jì)運(yùn)行時(shí)間,單位為100毫秒(一小時(shí)36 000)。810-800031-400通電或清除命令時(shí)重置為零。每當(dāng)裝置通電并按小時(shí)存儲(chǔ)時(shí),或啟用低功率待機(jī)模式離散輸入時(shí),時(shí)間就會(huì)累積。停機(jī)命令——810-800031-400使用維修工具強(qiáng)制裝置進(jìn)入停機(jī)狀態(tài)的命令。有助于進(jìn)入需要關(guān)閉設(shè)備的模式,如配置或調(diào)整用戶停止。
Status–Shutdown—810-800031-400General indication that a Shutdown condition exists, refer to the Status Error—Shutdowns tab sheet for the specific condition. Status–Low Pwr Stdby—General indication that the unit is in Low Power Standby Mode, refer to the Status Error—Shutdowns tab sheet for the specific condition. Service: Position Control The Position Control tab sheet contains position control information. Position Demand (%)—Indication of the actual position demand signal,810-800031-400 based on unit configuration, in percentage of the user calibrated range. Actual Posn (%)—Indication of the actual driver shaft output position, in percentage of the user calibrated range. Actual Posn (deg)—Indication of the actual driver shaft output position, in degrees rotation, relative to absolute shaft position.810-800031-400 For models I through IV, full counterclockwise is zero degrees and full clockwise is 75 degrees.
Time accumulates whenever the unit is powered up and is stored on an hourly basis or if the Low Power Standby Mode discrete input is enabled. 810-800031-400RunTime–100mSec—Accumulated runtime in units of 100 ms (36 000 in an hour). Resets to zero on a power-up or Clear command. Time accumulates whenever the unit is powered-up and is stored on an hourly basis or if the Low Power Standby 810-800031-400Mode discrete input is enabled. Shutdown Command—Command to force the unit into a shutdown condition using the Service Tool. Helpful for entering into modes that require the unit to be shut down, like Configure or Adjust User Stops. This command can be toggled between true and false. When toggled to true, the unit remains in a shutdown state until this parameter is set back to false or the power is 810-800031-400 cycled on the ProAct. Status–Alarm—General indication that an alarm condition exists, refer to the Status Error—Alarms tab sheet for the specific alarm condition.810-800031-400
Mode Int—Integer indication of the mode string (see above). ProAct Software Version—Displays the version number of the software installed. 810-800031-400Config ID—Displays the identification of the software system configurables. The default for this parameter is ProAct Digital Plus Configuration, however this string can be edited in the CFG file to a more meaningful name relative to the specific application setup and then downloaded back into the ProAct control. CAN ProAct Number—Indication of the identification number used in the CAN communication. Based on the status of the CAN ID Hi and Lo discrete inputs at power-up.810-800031-400 Elect Temp (°C)—Indication of the detected electronics temperature in degrees Celsius. RunTime–Clear Command—Command to clear the accumulated RunTime.810-800031-400 RunTime–Hours—Accumulated runtime hours since the last Run Time Clear command was issued.