故障可能是can過慢或can無信號,810-017016-001具體取決于接收到的信息數(shù)量。CAN輸入故障延遲(秒)默認(rèn)值=0.3秒(0.1到10)CAN請求信號故障延遲(以秒為單位)。該瞬態(tài)電流極限和穩(wěn)態(tài)電流都在最小或最大停止電流極限激活之前主動嘗試定位輸出——也就是說,在該極限接合之前,電流可能達(dá)到瞬態(tài)極限,然后是穩(wěn)態(tài)極限。這些設(shè)置僅在電流控制器上提供積分限制,因此實(shí)際電流可能超過此設(shè)置。高于此設(shè)置的當(dāng)前誤差與位置誤差需求成比例。一旦達(dá)到最大(或最?。O限,如果需求繼續(xù)增加(或減少),電流也將按比例增加。瞬態(tài)和穩(wěn)態(tài)電流限制仍然有效——電流不會超過這些限制。需求跟蹤誤差(%)默認(rèn)值=15%(1.0到100)當(dāng)使用冗余需求輸入(主和備份)時,需求輸入的跟蹤誤差調(diào)整。此設(shè)置是在發(fā)出跟蹤警報之前,控制需求和備用需求之間的最大差值(百分比)。810-017016-001差值必須超過“錯誤延遲”持續(xù)時間的“錯誤”百分比值才能生成警報。值為“100”將禁用報警。810-017016-001請求跟蹤錯誤延遲(秒)默認(rèn)值=1秒(0.1到10)跟蹤錯誤延遲,以秒為單位--請參閱請求跟蹤錯誤。
每當(dāng)裝置通電并按小時存儲時,或如果啟用了低功率備用模式離散輸入,則時間累積。停機(jī)命令使用維修工具強(qiáng)制裝置進(jìn)入停機(jī)狀態(tài)的命令。有助于進(jìn)入需要關(guān)閉裝置的模式,如配置或調(diào)整用戶停止。此命令可以在true和false之間切換。當(dāng)切換為true時,裝置將保持關(guān)機(jī)狀態(tài),810-017016-001直到此參數(shù)設(shè)置回false或ProAct上的電源循環(huán)。810-017016-001Status–報警存在報警條件的一般指示,具體報警條件請參閱Status Error Alarms(狀態(tài)錯誤報警)選項卡。Status–Shutdown(狀態(tài)–停機(jī))表示存在停機(jī)條件的一般指示,具體條件請參閱Status Error Shutdows(810-017016-001狀態(tài)錯誤停機(jī))選項卡頁。
A failure is determined if the PWM input frequency is above the ‘Fail Max’ hertz level for the ‘PwmIn Fail Delay’ time. PwmIn Fail Min Duty (%) default= 5 % (1 to 50) Duty cycle value at which the PWM input will be determined as failed. A failure is determined if the PWM input duty cycle is below the ‘Fail Min’ duty cycle level for the ‘PwmIn Fail Delay’ time.810-017016-001 PwmIn Fail Max Duty (%) default= 95 % (50 to 99) Duty cycle value at which the PWM input will be determined as failed. A failure is determined if the PWM input duty cycle is above the ‘Fail Max’ duty cycle level for the810-017016-001 ‘PwmIn Fail Delay’ time. PwmIn Fail Delay (sec) default = 0.1 sec (0.01 to 10) PWM input failure delay in seconds. PwmIn Filter default = 0.01 (0 to 1) Lag-tau filter adjustment on the PWM input. Stops—Min Stop Bias (deg) default = 0.5 degrees (–10 to 10) Electrical Stop adjustment in degrees of rotation. This is an actuator range adjustment setting for an extra “bias”810-017016-001 when at the minimum output position. This value biases the overall 0 % demand position. When positive,
810-017016-001this setting can help prevent the ProAct control's current driver from driving the actuator into the hard stops (mechanical limits) when the stop is reached by effectively moving the minimum stop position further from the mechanical stops (see also the Current Limit – Min Stop on the Service Hardware Adjustments tab sheet).810-017016-001 Setting this parameter to a negative value will force the output current to drive into the mechanical stop harder to ensure the valve is closed. Refer also to the Adjust User Stops section in the Service Mode.810-017016-001
Stops—Max Stop Bias (deg) default = 0.5 degrees (–10 to 10) Electrical Stop adjustment in degrees of rotation.810-017016-001 This is an actuator range adjustment setting for an extra “bias” when at the maximum output position. This value biases the overall 100 % demand position.810-017016-001 When positive, this setting can help prevent the ProAct control's current driver from driving the actuator into the hard stops (mechanical limits) when the stop is reached by effectively moving the minimum stop position further from the mechanical stops (see also the Current Limit – Max Stop on the Service Hardware Adjustments tab sheet).810-017016-001 Setting this parameter to a negative value will force the output current to drive into the mechanical stop harder to ensure the valve is opened. Refer also to the Adjust User Stops section in the Service Mode.810-017016-001