LAM 660-072825-625 射頻發(fā)生電源
產(chǎn)品概述:
660-072825-625執(zhí)行機構(gòu)慣性設(shè)置dflt=0(范圍0–25)執(zhí)行機構(gòu)/閥門慣性設(shè)置。此設(shè)置適用于慣性高于或低于默認值的系統(tǒng),如軸移動過大所示。660-072825-625零(0)設(shè)置基本上適用于未連接的軸,而增加設(shè)置意味著系統(tǒng)中的慣性更高。關(guān)于基于操縱桿尺寸的近似慣性設(shè)定值,660-072825-625。高摩擦系統(tǒng)dflt=false(false,true)內(nèi)部擾動觀測器控制器(dobs)啟用命令。通常設(shè)置為false,僅在高摩擦系統(tǒng)中需要。660-072825-625根據(jù)一般經(jīng)驗,當(dāng)需要超過2A的電流來移動致動器時,真實的設(shè)置將有助于控制。
執(zhí)行機構(gòu)慣性設(shè)置dflt=0(范圍0–25)執(zhí)行機構(gòu)/閥門慣性設(shè)置。此設(shè)置適用于慣性高于或低于默認值的系統(tǒng),如軸移動過大所示。零(0)設(shè)置基本上適用于未連接的軸,而增加設(shè)置意味著系統(tǒng)中的慣性更高。關(guān)于基于操縱桿尺寸的近似慣性設(shè)定值,660-072825-625。660-072825-625高摩擦系統(tǒng)dflt=false(false,true)內(nèi)部擾動觀測器控制器(dobs)啟用命令。通常設(shè)置為false,僅在高摩擦系統(tǒng)中需要。根據(jù)一般經(jīng)驗,當(dāng)需要超過2A的電流來移動致動器時,660-072825-625真實的設(shè)置將有助于控制。
Auto Status(自動狀態(tài))——自動用戶停止程序的字符串指示1=失敗0=禁用1=啟用2=尋找最小停止3=尋找最大停止4=停止設(shè)置自動狀態(tài)Int——自動狀態(tài)字符串的整數(shù)指示(見上文)。手動啟用dflt=false命令啟用手動用戶校準。當(dāng)為true時,手動設(shè)定位置(%)將主動控制駕駛員輸出至指令位置。此模式也可用于筆劃輸出。手動設(shè)置位置(%)默認為50%(-10到110)手動位置需求。當(dāng)啟用手動模式時,此需求設(shè)置處于活動狀態(tài)??捎糜谠O(shè)置止動器和沖程執(zhí)行器輸出。手動狀態(tài)——手動用戶停止程序的字符串指示1=失敗0=禁用1=啟用2=最小停止集3=最大停止集手動狀態(tài)Int——手動狀態(tài)字符串的整數(shù)指示
If successful, the Calibration Status will indicate the calibration is complete. The status will indicate ‘failed’ if the calibration is unsuccessful. 12. Verify Calibration. This can be done by hand by moving the rack from min to max and observing the position readout (Service Tool or analog out) or by stetting the Manual Enable to true and positioning the output using the Manual Set Position variable. 13. Adjust Dynamics. Adjust the Actuator Inertia Setting for proper system performance. Increasing the setting implies a higher inertia in the system and results in a higher gain in the actuator. Verify the setting with the Actuator Inertia Test Execute command. Refer to Table 9-1 for an approximate inertia setting based on lever size. 14. Optionally, set the offset (bias) desired at each stop. The Min Stop Bias and Max Stop Bias parameters are available in the Hardware Adjustments to basically provide an electrical stop within the user calibrated stop settings. This offset is in degrees of travel and can be adjusted anytime. Refer to Figure 9-5 and Service Mode: Hardware adjustments later in this chapter.
Select the desired calibration mode. There are 2 modes, a manual stroking mode and an automatic mode. Refer to Figures 9-7 and 9-8. If the Auto mode is selected, steps 7 through 11 will occur automatically without any user input required. Auto Mode is enabled by setting “Auto Execute” to true. 7. There are two methods to manually move the output between min and max position: by hand or by using the Manual Set Position. To use the Manual Set Position, the Manual enable must be set to true. Using the Manual Set Position to position the ProAct, decrease the demand setting until the actuator is positioned at the minimum stop or, by hand, push the output into the min stop. 8. Set the At Min Position parameter to true to allow the Control to record the Min position setting. 9. Increase the Manual Set Position setting until the actuator is positioned at the maximum stop or, by hand, push the output into the max stop. 10. Set the At Max Position parameter to true to allow the Control to record the Max position setting. 11. When both Min and Max have been successfully calibrated, set the Enable Manual Stroke back to false (if a Manual Calibration is enabled).
To enter the User Calibration mode, the unit must be shut down and a password must be entered. For an overview of the User Calibration, refer to the attached flowcharts (Figures 9-7 and 9-8). Procedure to Adjust Stops and Dynamics 1. Connect PC to ProAct using an RS-232 Null Modem cable. 2. Run Servlink on the PC and connect to the ProAct control. Refer to the Service Tool chapter for details on Servlink setting and connection in the Getting Started section. 3. Open Watch Window or alternative programming tool on the PC. 4. Shut down the ProAct by either issuing a Shutdown Command from the PC (on the Unit Status tab sheet) or by opening the ProAct Low Power Standby Mode Discrete Input. Either method puts the unit in a shutdown state, which is a permissive for the Adjust User Stops mode. 5. Enter the Adjust User Stops Password (Mode Password) from the Service: Adjust User Stops tab sheet. The ProAct will provide feedback that the user stops calibration mode has been successfully entered through the Operational Mode and Mode Enabled indications.