LAM 605-707109-012 Plc網(wǎng)絡(luò)接口模塊
產(chǎn)品概述:
校準(zhǔn)完成后,將605-707109-012 Plc模式退出)設(shè)置為true,以返回到上一個(gè)(停機(jī))模式。服務(wù):調(diào)整用戶停止(必須關(guān)閉并輸入密碼)此類別提供在調(diào)整用戶停止模式中更改參數(shù)的權(quán)限。605-707109-012 Plc。它提供了自動(dòng)和手動(dòng)設(shè)置停止、慣性設(shè)置和測(cè)試能力以及退出命令的方式,給出模式狀態(tài),并識(shí)別配置中的錯(cuò)誤。
模式密碼dflt=0調(diào)整用戶停止模式的密碼輸入命令。605-707109-012 Plc要輸入值,請(qǐng)突出顯示或刪除默認(rèn)值(“0”),然后使用鍵盤輸入數(shù)字密碼。當(dāng)按下回車鍵或選擇輸入右側(cè)的等號(hào)時(shí),接受輸入。輸入后,密碼將返回零。如果接受并關(guān)閉裝置,“啟用”指示將為真。有關(guān)維修工具密碼,請(qǐng)參閱附錄。模式啟用(僅狀態(tài)指示)調(diào)整用戶停止模式啟用指示(真/假)。當(dāng)模式啟用時(shí),參數(shù)為true——這表示可以更改“調(diào)整用戶停止”模式參數(shù)。如果為false,則只能查看參數(shù),而不能調(diào)整參數(shù)。模式退出dflt=false(僅限瞬時(shí)真命令)退出命令。605-707109-012 Plc設(shè)置為true可退出“調(diào)整用戶停止”模式。這將禁用在此模式下更改參數(shù)的功能?!巴顺觥眳?shù)在退出完成后自動(dòng)返回false。Auto Execute dflt=false(僅限瞬時(shí)真命令)執(zhí)行自動(dòng)“尋止器”程序的命令。當(dāng)設(shè)置為true時(shí),605-707109-012 Plc輸出移動(dòng)到最小和最大位置,并自動(dòng)確定停止。Status字符串指示當(dāng)前執(zhí)行步驟。設(shè)置停止時(shí),該命令會(huì)自動(dòng)設(shè)置回false。
選擇所需的校準(zhǔn)模式。有兩種模式,手動(dòng)沖程模式和自動(dòng)模式。605-707109-012。如果選擇了自動(dòng)模式,步驟7至11將自動(dòng)執(zhí)行,無需任何用戶輸入。通過將“自動(dòng)執(zhí)行”設(shè)置為true,605-707109-012可啟用自動(dòng)模式。7.有兩種方法可以手動(dòng)在最小和最大位置之間移動(dòng)輸出:手動(dòng)或使用手動(dòng)設(shè)置位置。要使用手動(dòng)設(shè)置位置,必須將手動(dòng)啟用設(shè)置為true。使用手動(dòng)設(shè)置位置定位ProAct,降低需求設(shè)置,直到致動(dòng)器定位在最小停止位置,或者用手將輸出推入最小停止位置。8.將At Min Position(在最小位置)參數(shù)設(shè)置為true,以允許Control記錄最小位置設(shè)置。9.增加手動(dòng)設(shè)定位置設(shè)置,直到致動(dòng)器定位在最大停止位置,或者用手將輸出推入最大停止位置。10.將At Max Position(在最大位置)參數(shù)設(shè)置為true,以允許控制記錄最大位置設(shè)置。11.當(dāng)Min和Max均已成功校準(zhǔn)時(shí),將Enable Manual Stroke(啟用手動(dòng)沖程)設(shè)置回false(如果啟用手動(dòng)校準(zhǔn))。如果成功,Calibration Status(校準(zhǔn)狀態(tài))將指示校準(zhǔn)已完成。如果校準(zhǔn)不成功,狀態(tài)將指示“失敗”。12.驗(yàn)證校準(zhǔn)。這可以手動(dòng)完成,方法是將機(jī)架從最小值移動(dòng)到最大值,觀察位置讀數(shù)(維修工具或模擬輸出),或?qū)⑹謩?dòng)啟用設(shè)置為真,并使用手動(dòng)設(shè)置位置變量定位輸出。605-707109-01213.調(diào)整動(dòng)態(tài)。調(diào)整執(zhí)行器慣性設(shè)置以獲得正確的系統(tǒng)性能。增加設(shè)置意味著系統(tǒng)中的慣性更高,并導(dǎo)致致動(dòng)器中的增益更高。使用執(zhí)行器慣性測(cè)試執(zhí)行命令驗(yàn)證設(shè)置。關(guān)于基于操縱桿尺寸的近似慣性設(shè)置,請(qǐng)參閱表9-1。14.可選地,在每個(gè)停止處設(shè)置所需的偏移(偏置)。605-707109-012“硬件調(diào)整”中提供了“最小停止偏移”和“最大停止偏移”參數(shù),基本上可以在用戶校準(zhǔn)的停止設(shè)置內(nèi)提供電氣停止。該偏移以行程的度數(shù)為單位,可以隨時(shí)調(diào)整。請(qǐng)參閱本章后面的圖9-5和維修模式:硬件調(diào)整。
This setting inverts the PWM input values to read the percentage of the time low rather than the percentage of the time high. Adjusting User Stops and Dynamics Introduction The User Calibration mode of the Service Tool provides the capability to set the min and max position to match the rigging of the actuator and valve. Both automatic and manual procedures are available to perform this setup. 605-707109-012This calibration must be done prior to operation of the unit.605-707109-012 If this procedure is not done, the actuator will be defaulted such that (0 to 100) % position demand will correspond to 0–75 degrees rotation. Refer to Figure 9-4. Once the user calibration is performed, this procedure stores the active min and max positions into non-volatile memory where it is retained until a new calibration is performed. In addition, 605-707109-012this mode can be used to verify the setup/calibration by providing a manual stroking mechanism.
AnlgIn 200 Min Value (mA) dflt= 20 mA(range 0.0–200) Analog Input Minimum Demand Value in mA. This setting corresponds to the milliamp signal that would demand the actuator to be fully closed (0 %) (should be less than the ’AnlgIn 200 Max Value (mA)’ setting).605-707109-012 AnlgIn 200 Max Value (mA) dflt=180 mA (range 0.0–200) Analog Input Maximum Demand Value in mA. This setting corresponds to the milliamp signal that would demand the actuator to be fully opened (100 %) (should be greater than the ’AnlgIn 200 Min Value (mA)’ setting). CAN DataRate default = 1(1, 3) CAN data rate setting in kbps. 605-707109-012Selection options: 1=250, 2=500, 3=1000 kbps. CAN Extensions default = 1 (0, 1) CAN Extension Configuration. This determines the messages of the CAN communications. The ProAct uses J1939 CAN but this setting sets up the actual Parameter Group Numbers (PGNs) and Suspect Parameter Numbers (SPNs) to be used over the comm link. Selection options: 0=Disable Can communications, 1=Set#1, 2=Set#2, etc. (must be greater than zero if CAN demand is configured). PwmIn Min Duty (%) default = 10 % (range 10–90) PWM Minimum actuator position Duty Cycle setting in percent. This setting corresponds to the duty cycle that would demand the actuator to be fully closed (0 %) (must be less than the ’PwmIn Max Duty (%)’ setting). PwmIn Max Duty (%) default 90 % (range 10–90) PWM Maximum actuator position Duty Cycle setting in percent. This setting corresponds to the duty cycle that would demand the actuator to be fully open (100 %) (must be greater than the ‘PwmIn Min Duty (%)’ setting).605-707109-012 PwmIn Frequency (Hz) dflt 1000 Hz (100–3000) Nominal PWM signal frequency in hertz. PwmIn Invert Input Signal dflt =false (false, true) Invert PWM Signal option. This configuration setting is available for systems that do not have a pull-up in their PWM output (refer to the hardware PWM section for details).
Demand—Primary Source dflt = 3 (1, 3) Select the source of the primary demand input. Selection options: 1=CAN, 2=PWM, 3=Analog. Demand—Backup Source dflt = 2 (0, 3) Select the source of the backup demand input. Selection options: 0= Not Used, 1=CAN, 2=PWM, 3=Analog605-707109-012 (Primary and Backup demand sources must be different). AnlgIn 20 Min Value (mA) dflt=4 mA (range 0.0–25) Analog Input Minimum Demand Value in mA. 605-707109-012This setting corresponds to the milliamp signal that would demand the actuator to be fully closed (0 %) (should be less than the ’605-707109-012AnlgIn 20 Max Value (mA)’ setting). AnlgIn 20 Max Value (mA) dflt=20 mA (range 0.0–25) Analog Input Maximum Demand Value in mA. This setting corresponds to the milliamp signal that would demand the actuator to be fully opened (100 %) (should be greater than the ’605-707109-012AnlgIn 20 Min Value (mA)’ setting).