LAM 605-707109-002 半導(dǎo)體板

 LAM | 2024-01-15 11:02:13| 小編  提示:點擊圖片可以放大

LAM 605-707109-002 半導(dǎo)體板

產(chǎn)品概述:

605-707109-002要進(jìn)入用戶校準(zhǔn)模式,必須關(guān)閉設(shè)備并輸入密碼。有關(guān)用戶校準(zhǔn)的概述,請參閱所附的流程圖(圖9-7和9-8)。調(diào)整制動器和動態(tài)系統(tǒng)的步驟1。使用605-707109-002零調(diào)制解調(diào)器電纜將PC連接到605-707109-002。2.在電腦上運行605-707109-002并連接到ProAct控件。請參閱維修工具一章,了解入門部分中有關(guān)Servlink設(shè)置和連接的詳細(xì)信息。3.打開電腦上的“監(jiān)視窗口”或其他編程工具。4。605-707109-002通過PC發(fā)出關(guān)閉命令(在機組狀態(tài)選項卡頁上)或打開ProAct低功率待機模式離散輸入來關(guān)閉ProAct。任何一種方法都會使機組處于停機狀態(tài),這是對調(diào)整用戶停機模式的許可。5.從服務(wù):調(diào)整用戶停止選項卡工作表中輸入調(diào)整用戶停止密碼(模式密碼)。605-707109-002將提供反饋,表明用戶已通過操作模式和模式啟用指示成功進(jìn)入停止校準(zhǔn)模式。

LAM 605-707109-012(1).jpg


605-707109-002頻率(Hz)dflt 1000 Hz(100–3000)標(biāo)稱PWM信號頻率(赫茲)。PwmIn Invert Input Signal dflt=false(false,true)Invert PWM Signal(反相PWM信號)選項。此配置設(shè)置適用于605-707109-002輸出中沒有上拉的系統(tǒng)(有關(guān)詳細(xì)信息,請參閱硬件PWM部分)。此設(shè)置反轉(zhuǎn)PWM輸入值以讀取時間低的百分比,而不是時間高的百分比。調(diào)整用戶停止和動力學(xué)簡介維修工具的用戶校準(zhǔn)模式提供了設(shè)置最小和最大位置的功能,以匹配致動器和閥門的索具。自動和手動程序都可用于執(zhí)行此設(shè)置。此校準(zhǔn)必須在裝置運行之前完成。如果不執(zhí)行此程序,執(zhí)行機構(gòu)將默認(rèn)為(0到100)%的位置需求將對應(yīng)0到75度的旋轉(zhuǎn)。605-707109-002。一旦執(zhí)行了用戶校準(zhǔn),此程序?qū)⒒顒拥淖钚『妥畲笪恢么鎯Φ椒且资源鎯ζ髦?,在?zhí)行新的校準(zhǔn)之前,該位置一直保留。此外,此模式可用于通過提供手動沖程機構(gòu)來驗證設(shè)置/校準(zhǔn)。


XVME-560 70560-001(1).jpg


Temp Protect Enable dflt =true (false, true) Temperature Protection Configuration. This enables current limiting based on temperature and is a combination of temperature protection and compensation. 605-707109-002When set to true (recommended), protection is provided to limit the drive current output when the internal actuator temperature exceeds the absolute failure levels. When set to false, this protection is bypassed. An alarm is logged when absolute failure protection temperature limiting is active. 605-707109-002The same algorithm not only limits the current at very high temperatures, but allows additional current at very low temperatures as well (refer to Current Limiting based on Temperature description in Chapter 5). Configure: Demand Setup The Demand Setup sets the ProAct control’s primary and backup demands.605-707109-002 Refer to Figure 9-3. Additional demand parameters are available in the Adjustments Mode.


1.15-1.png



When set to false, the condition of the Run Enable (Low Power Standby Mode) contacts will not affect the Status Output. Run Enable – Closed to Run dflt=true (false, true) (This parameter only available with ProAct Software Version 2.20 special firmware Woodward part number 5418-2590) 605-707109-002(Check the version number under Service: Unit Status:) When set to true, the run enable contacts will be closed for run mode, and open for Low Power Standby Mode. When set to false, the run enable contacts will be open for run mode, and closed for Low Power Standby Mode. Shutdown Action dflt = 3 (1,3) Select the action to be performed when a shutdown condition is detected. Selection options: 1=Min, 2=Max, 3=Pwr Down. (refer to Shutdown description TBD).605-707109-002 Temp Alarm SP (°C) dflt = 95 °C (50, 150) High Temperature Alarm set point in degrees Celsius. This alarm is based on the internal electronics temperature.605-707109-002 Refer to the alarms section for details. Temp Alarm Delay (sec) dflt = 1 sec (0, 10) High temperature alarm delay in seconds.




圖片1_副本.png


 

Actuator Type dflt = 3 (1=ProAct1, 2=ProAct2, … 4=ProAct4) ProAct Actuator Type configuration. This is set to the appropriate ProAct actuator (e.g. ProAct Model 4 would be set to ‘4’). 605-707109-002Actuator CCW Direction dflt = false (false=CW, true=CCW) ProAct Actuator Direction configuration—clockwise vs. counter-clockwise—as seen from the shaft end of the actuator. Actuator Inertia Setting dflt =0 (range 0–25) Actuator/valve inertia setting.605-707109-002 This setting is available for systems with higher or lower inertia than the default as indicated by excessive shaft movement. A zero (0) setting is basically for an unconnected shaft, whereas, increasing the setting implies a higher inertia in the system. This parameter can also be tuned and tested in the Service Mode—see Adjusting and Testing Actuator Dynamics in the Adjust User Stops section for details (see Figure 9-8 for more details). High Friction System dflt =false (false, true) Internal Disturbance Observer Controller (dobs) Enable command. Normally set to false, only needed in high friction systems. This parameter can also be tuned in the Service Mode to determine if it is needed—see Adjusting and Testing Actuator Dynamics in the Adjust User Stops section for details (see Figure 9-8 for more details). DiscreteOut Alarms Enabled dflt=true (false, true) Discrete Output configuration setting. When false, only Shutdowns will activate the discrete output. When true, any alarm or shutdown condition will activate the discrete output. Discrete Out Includes Runenable [Run/Enable] dflt=true (false, true)605-707109-002 (This parameter only available with ProAct Software Version 2.10 or later) (Check the version number under Service: Unit Status:) When set to true, when the Run Enable Discrete Input (Low Power Standby Mode) contacts are opened, the Status Output will also open.