LAM 605-707109-001 控制板

 LAM | 2024-01-15 10:57:07| 小編  提示:點(diǎn)擊圖片可以放大

LAM 605-707109-001 控制板

產(chǎn)品概述:

605-707109-001200最小值(mA)dflt=20 mA(范圍0.0–200)模擬輸入最小需求值,單位為mA。此設(shè)置對(duì)應(yīng)于要求致動(dòng)器完全關(guān)閉(0%)的毫安信號(hào)(應(yīng)小于“605-707109-001”設(shè)置)。AnlgIn 200最大值(mA)dflt=180 mA(范圍0.0–200)模擬輸入最大需求值,單位為mA。此設(shè)置對(duì)應(yīng)于要求致動(dòng)器完全打開(100%)的毫安信號(hào)(應(yīng)大于“AnlgIn 200Min Value(mA)”設(shè)置)。CAN數(shù)據(jù)速率默認(rèn)值=1(1,3)CAN數(shù)據(jù)速率設(shè)置,單位為kbps。選擇選項(xiàng):1=250、2=500、3=1000 kbps。CAN擴(kuò)展默認(rèn)值=1(0,1)CAN擴(kuò)展配置。這決定了605-707109-001通信的消息。605-707109-001使用J1939 CAN,但此設(shè)置設(shè)置了要通過通信鏈路使用的實(shí)際參數(shù)組號(hào)(PGN)和可疑參數(shù)號(hào)(SPN)。選擇選項(xiàng):0=禁用Can通信,1=設(shè)置#1,2=設(shè)置#2等(如果配置了Can需求,則必須大于零)。PwmIn最小占空比(%)默認(rèn)值=10%(范圍10–90)PWM最小執(zhí)行器位置占空比設(shè)置,單位為百分比。該設(shè)置對(duì)應(yīng)于要求致動(dòng)器完全關(guān)閉的占空比(0%)(必須小于“PwmIn Max duty(%)”設(shè)置)。605-707109-001最大占空比(%)默認(rèn)為90%(范圍10–90)PWM最大執(zhí)行器位置占空比設(shè)置,單位為百分比。該設(shè)置對(duì)應(yīng)于要求執(zhí)行機(jī)構(gòu)全開(100%)的占空比(必須大于“PwmIn Min duty(%)”設(shè)置)。

LAM 605-707109-012(1).jpg


溫度保護(hù)啟用dflt=true(false,true)溫度保護(hù)配置。這實(shí)現(xiàn)了基于溫度的電流限制,并且是溫度保護(hù)和補(bǔ)償?shù)慕Y(jié)合。當(dāng)設(shè)置為true(推薦)時(shí),當(dāng)內(nèi)部執(zhí)行器溫度超過絕對(duì)故障水平時(shí),提供保護(hù)以限制驅(qū)動(dòng)電流輸出。605-707109-001當(dāng)設(shè)置為false時(shí),將繞過此保護(hù)。當(dāng)絕對(duì)故障保護(hù)溫度限制激活時(shí),會(huì)記錄報(bào)警。同樣的算法不僅在非常高的溫度下限制電流,而且在非常低的溫度下也允許額外的電流(參見第5章中基于溫度的電流限制描述)。605-707109-001配置:需求設(shè)置需求設(shè)置設(shè)置ProAct控件的主要和備份需求。參見圖9-3。調(diào)整模式中提供了其他需求參數(shù)。605-707109-001


需求——主要來源dflt=3(1,3)選擇主要需求輸入的來源。選擇選項(xiàng):1=CAN,2=PWM,3=模擬。Demand--備份源dflt=2(0,3)選擇備份請(qǐng)求輸入的源。選擇選項(xiàng):0=未使用,1=CAN,2=PWM,3=模擬605-707109-001(主和備用需求源必須不同)。AnlgIn 20最小值(mA)dflt=4 mA(范圍0.0–25)模擬輸入最小需求值,單位為mA。此設(shè)置對(duì)應(yīng)于要求執(zhí)行機(jī)構(gòu)完全關(guān)閉(0%)的毫安信號(hào)(應(yīng)小于“605-707109-001 20最大值(mA”設(shè)置)。AnlgIn 20最大值(mA)dflt=20 mA(范圍0.0–25)模擬輸入最大需求值,單位為mA。此設(shè)置對(duì)應(yīng)于要求執(zhí)行機(jī)構(gòu)完全打開(100%)的毫安信號(hào)(應(yīng)大于“AnlgIn 20最小值(毫安)”設(shè)置)。


XVME-560 70560-001(1).jpg


Enabled (status indication only) Configure Mode Enabled Indication (true/false). Parameter is true when the mode is enabled – this indicates Configure mode parameters can be changed. When false, parameters can only be viewed – not adjusted. Exit dflt = false (momentary true command only) Exit command. Set to true to exit the Configure mode. 605-707109-001This disables the ability to make changes to parameters in this mode. The ‘Exit’ parameter automatically returns to false when the exit is completed. Error Code (status indication only) Integer Indication of the status of the configuration (see also Error Info). An error in the configuration will not allow the actuator to operate and will result in a Configuration Error Shutdown. Error Code Interpretation (same as Error Info below) 0 No errors in configuration 101 Primary / Backup signal selection same 102 Invalid primary demand signal selection 103 Invalid backup demand signal selection 104 Actuator Inertia setting value too large 105 Invalid Actuator type selection 106 Invalid PwmIn max/min duty values 107 Invalid AnalogIn max/min values 108 CAN Extensions must be non-zero Error Info (status indication only) String Indication of the status of the configuration (see also Error Code). An error in the configuration will not allow the actuator to operate and will result in a Configuration Error Shutdown (see information on shutdowns). 605-707109-001Shutdown Command dflt = false (false, true) RS-232 Command to shut the actuator driver down. Refer to shutdowns. Configure: Unit Setup The Unit Setup category sets critical actuator and controller information.605-707109-001 Refer to Figure 9-2. Additional actuator parameters are available in the Service Mode (see ‘Hardware Adjustments’).


1.15-1.png


106 Invalid PwmIn max/min duty values 605-707109-001(the PWM demand input setting for min duty cycle must be less than the max value) 107 Invalid AnalogIn max/min values (the analog input demand input setting for min must be less than the max value) 108 CAN Extensions must be non-zero (the CAN Extensions setting cannot be zero when CAN is configured as a demand signal. An Extension setting of zero disables the CAN transmissions.) Configure Mode Parameters Overview The Configure Mode is used to set up the parameters for the specific application of the ProAct control. For example, the direction of shaft rotation,605-707109-001 type of actuator, and primary/backup demand selections are set in the Configure mode. This mode can be accessed at any time but parameters can only be changed when the unit is shut down and the password is entered (see Password and Enabled parameters in the Mode category).

 

Password dflt =0 Password input command for the Configure mode. To enter a value, highlight or delete the default value (‘0’) and use the keypad to enter the numeric password. 605-707109-001The input is accepted when the enter key is pressed or the equals sign to the right of the input is selected. When entered, the password returns to zero. If accepted and the unit is shut down, the ‘Enabled’ indication will be true. Refer to the Appendix for Service Tool passwords.

 



圖片1_副本.png


 

Exiting Configure Mode Select the Configure Mode tab sheet and set the EXIT value to ‘true’. Return the unit to a running (operational) state by setting the Shutdown Command value back to ‘false’ or by closing the Low Power Standby Mode discrete input. The Service Mode / Unit Status will display ‘running’ if successful (refer to the Service Mode Details section). If an error was made in the unit’s configuration, a Config Error shutdown will hold the driver in a shutdown state.605-707109-001 The exact cause of the Configuration Error is identified on the Configure Mode tab sheet (see Configuration Error section). Configuration Error Upon completion of the configuration, a validity check is performed. If an error is detected, the Config Error shutdown is issued and the unit will not run until it is cleared. The cause of the Configuration Error can be determined from the Error Code and Error Info values on the Configure Mode tab sheet. Error Code Error Info (displayed text) 0 No errors in configuration 101 Primary / Backup signal selection same (the primary demand and backup demands are configured for the same source) 102 Invalid primary demand signal selection (the primary demand selection is configured for an out of range value) 103 Invalid backup demand signal selection605-707109-001 (the backup demand selection is configured for an out of range value) 104 Actuator Inertia setting value too large (the actuator inertia setting selection is configured for an out of range value) 105 Invalid Actuator type selection (the actuator type is configured for an out of range value)